Solar panels in Balderton, designed on a free call.
A 12-panel roof in Balderton makes about 6,360 kWh a year and costs £6,360 installed; a free 30-minute video call sizes it to yours.
Get my free quote
Three details. We call or text within one working day to book your free 30-minute design call, on video or by phone if you prefer.
or call 07782 219224
- Free 30-minute video design call
- Priced before anyone visits
- Installed by our MCS-certified, fully insured teams
Sunlight in Balderton, in numbers
Balderton's best month is May, at 124.2 kWh per kWp; December manages 34.5. Over the year that comes to 1,000 kWh per kWp, 1% above our Nottinghamshire county estimate.
Generation per kWp, month by month
Show the monthly figures
| Month | kWh/kWp |
|---|---|
| January | 36.9 |
| February | 52.2 |
| March | 87.2 |
| April | 112 |
| May | 124 |
| June | 117 |
| July | 122 |
| August | 111 |
| September | 93.2 |
| October | 64.5 |
| November | 45.1 |
| December | 34.5 |
Source: PVGIS v5.2 (European Commission JRC), SARAH3 database, 1 kWp, 14% system loss, 35 degree pitch, due south, checked September 2026.
For scale: 1,000 kWh per kWp in Balderton against 925, our GB average (the mean of our 85 county PVGIS estimates), which puts Balderton 8% above it.
How Balderton compares
Small towns rarely get published solar figures, so here are the numbers for Balderton. It is one of 29 Nottinghamshire towns we track, and it ranks 1st of 29 for solar yield, a town of 9,816 people in the House of Commons Library settlement data. PVGIS gives its roofs 1,000 kWh per kWp a year, 2.74 peak sun hours a day averaged across the seasons, and the standard 12 panel model turns that into £898 of year one benefit, £247 of it from your own generation and £651 from export at 12p.
Treat these as calibration rather than a quote. The calculator below runs the same model, opened on Balderton's own yield, and prices a 12 panel system at £6,360 installed before any battery. Your free design call reworks every number for your actual roof, its shading and your usage.
Planning applications here go through Newark and Sherwood; nationally, the House of Commons Library classes Balderton as a small town.
The charger is in the installed price but left out of payback: charging savings depend on your mileage and tariff, which the design call models properly.
Your real roof and usage, worked through on a free 30-minute video call. Use the full form or leave three details below.
Price this for your roof
Three details. We call or text within one working day to book your free 30-minute design call, on video or by phone if you prefer.
Modelled for Balderton at 53.0578, -0.78364 on PVGIS data, with imports valued at 26.32p/kWh and solar at £1,000 per kWp installed. Sources and assumptions: help page.
NGED and your Balderton connection
The distribution network operator (DNO) for Balderton is National Grid Electricity Distribution (NGED), which runs the East Midlands licence area.
G98 is the simple route. If the inverter, plus any battery, stays at or under 3.68kW per phase, NGED only has to be told within 28 days after the system is commissioned.
Above that, G99 means applying before the work is booked. NGED's guaranteed standards give 45 working days for a low voltage generation quotation, with £80 paid for each working day late.
Sources: NESO DNO licence areas (3 May 2024); NGED, guaranteed standards of performance table, checked 25 September 2026. G98 vs G99, explained.

Heat pumps and EV charging in Balderton
A heat pump in Balderton
Heating demand peaks when solar is weakest. In Balderton, a 12-panel system makes about 220 kWh in December and 230 kWh in January, a fraction of its 790 kWh in May, which is why a heat pump here is costed on its tariff first.
The Boiler Upgrade Scheme, open in England and Wales, takes £7,500 off an air source or ground source heat pump, or £2,500 off an air-to-air unit. Homes on oil or LPG with no mains gas get £1,500 more until March 2027 (gov.uk, checked 28 September 2026).
Charging an EV in Balderton
Balderton's May output, about 790 kWh from 12 panels, is several times the 70 kWh or so a typical home uses in daylight that month on our calculator's settings. Daytime charging turns that surplus into miles.
If you rent, or own a flat, and have private off-street parking, the government chargepoint grant covers 75% of the cost, capped at £500 a socket, until 31 March 2027 (gov.uk, checked 28 September 2026). The calculator above prices a 7.4kW smart charger from £1,100 installed.
Installed prices, the same in every town
Every system is designed around your roof on the free call before anything is fitted.
Solar panel servicing and repair in Balderton
If a system in Balderton is underperforming, start with the guides below: repair benchmarks, service scope, and the inverter question.
Balderton solar questions
How much energy would 12 solar panels make in Balderton?
Balderton averages 2.74 peak sun hours a day, which PVGIS turns into 1,000 kWh per kWp a year. On a 12-panel, 6.36 kWp roof that is about 6,360 kWh, 68% of it between April and September.
Is solar more expensive in Balderton?
Prices on this site are the same everywhere: £1,000 per kWp installed, which puts a 12-panel system at £6,360 in Balderton, and a Duracell Dura16 installed with solar at £4,450 on top. The local part is generation, about 6,360 kWh a year here, which is what drives payback.
Who is the network operator in Balderton, and do I need a G99 application?
The operator is National Grid Electricity Distribution (NGED). Most home systems use the G98 route, a notification within 28 days of switch-on for up to 3.68kW per phase, so nothing waits on the network. Above that, G99 applies and has to be granted first. NGED's guaranteed standards give 45 working days for a low voltage generation quotation, with £80 paid for each working day late. Your design call checks which route yours needs.
What could I earn from exporting in Balderton?
On the 12p export scenario, a 12-panel system in Balderton sends about 5,423 kWh a year to the grid, worth around £651. The export rates table compares what each supplier pays.
How does solar perform in Balderton in the winter months?
December is the weakest month in Balderton: about 220 kWh from 12 panels, against 790 kWh in May. The panels still generate on bright winter days; they just cover a smaller share of what the house uses.
How Balderton compares with its neighbours
How the towns nearest Balderton compare on the same PVGIS settings, closest first.
| Town | kWh per kWp a year | vs Balderton |
|---|---|---|
| Balderton | 1,000 | this town |
| Newark-on-Trent | 999 | −1 kWh |
| Bingham | 993 | −7 kWh |
| Grantham | 1,013 | +13 kWh |
| North Hykeham | 1,011 | +11 kWh |
| Calverton | 986 | −14 kWh |
| Radcliffe on Trent | 991 | −9 kWh |
PVGIS v5.2 for each town centroid, identical assumptions throughout. A few kWh either way is weather-year noise; a spread beyond about 30 kWh per kWp is real geography.
Also for Balderton: Solar panels in Balderton from OVO Solar & Battery
See a number before you speak to anyone
Answer a few questions about your roof and usage and see an instant solar and battery estimate. No email needed to see the result.
Reading for Balderton homeowners
Sourced, dated and written by us. The same ground we cover on your free call.
Back contact solar panels, explained for a UK roof
What back contact changes on a roof, compared fairly with TOPCon, with the makers' own claims labelled.
Read the guide →Tesla Powerwall 3 vs Duracell Dura16: which fits your home?
The two packages we actually price, compared on the numbers that decide it.
Read the guide →Smart charge point regulations, explained
Why your charger arrives pre-set to charge overnight, and why it waits before it starts.
Read the guide →What MCS certification actually buys you on a heat pump job
The gate on the £7,500 grant, the design standard behind your running costs, and the noise sign-off.
Read the guide →Choosing a tariff when you have solar, a battery and an EV
Solar, battery and EV want different tariffs. How to work out which one to protect.
Read the guide →NAPIT, NICEIC and competent person schemes: who tells building control about your solar
Solar work is notifiable. A competent person scheme means your installation team notifies, not you.
Read the guide →Get my free quote
Takes about two minutes. We call or text within one working day to book your free 30-minute video design call at a time that suits you. We design it around your roof and your numbers, and our MCS-certified, fully insured installation teams install it.